
Garage pedestrian door size | The Building Code Forum
Nov 24, 2025 · I have a single car garage with a sectional overhead door, I have space on one stucco wall for a 24 x 75 pedestrian door. will that size be acceptable since it is not the main egress door?
S-1 & S-2 Regarding Parking Garage - The Building Code Forum
Jan 7, 2015 · Because this garage is over 1,000 SF it falls outside the scope of a "private garage" and is, for code purposes, a "public garage". Section 311.3 Classifies "Parking garages, open or …
Equipment Bollard in a Residential Garage - The Building Code Forum
Oct 20, 2009 · Re: Equipment Bollard in a Residential Garage We have a minimum 36 inch high 2" schedule 40 iron pipe embedded in the garage slab. We also have two alternates that are wheel …
2024 Portal Frames | The Building Code Forum
Apr 1, 2024 · In the picture provided, I would say that is still a single portal frame opening. I think the intent was to prevent two portal frames immediately adjacent to each other using a common header. …
Garage Open Air Calculations - The Building Code Forum
Dec 18, 2011 · I am designing a garage, and trying to achieve natural ventilation. I think I have achieved the required 20% open, as well as 40% perimeter open as per IBC 2006, but what if your garage is …
Egress through a garage. | The Building Code Forum
Apr 9, 2015 · A detached garage is not going to require egress in the same manner as a habitable space. How do you egress out of a garage itself?
Garage Floor Drain - The Building Code Forum
Dec 9, 2018 · Needing some info on garage floor drain. Have read codes that garage floor must slope out or to a drain. Have new residential construction with attached garage. The builder installed what …
Pex/pvc pipes in a garage - The Building Code Forum
Jun 11, 2019 · Are pex/ pvc water and waste lines allowed to run (exposed) through a garage? I know the code requires ducts to be min. 26 gage metal, and other penetrations between garage and house …
Minimum Floor Slope for Drainage - The Building Code Forum
Oct 19, 2009 · Irc The building code requires that a garage floor be sloped towards the door, but does not specify a minimum slope. It is usually 1/8” to 1/4” per foot. Here is the citation from the …
Step from garage into House?? | The Building Code Forum
Jul 22, 2019 · I do not see anywhere in the IRC 2015 that requires a step from the garage into the house. I saw the opening penetrations R302.5 & Garage section R309. Is the step still a requirement …