Romex | Information by Electrical Professionals for Electrical ...
Sep 6, 2013 · In the code book it says that you can install Romex if permitted as a Type 3, 4 or 5 building, but if it is permitted as a type 1 building you can not install Romex. Although IF the building …
Romex wiring in garage | Information by Electrical Professionals for ...
May 8, 2015 · I'm buying a house and there is romex wiring run through the garage. The installation was approved by the township in 1987 when it was installed. Current standards requireany type of non …
That old Romex question again. | Information by Electrical ...
Mar 12, 2022 · Hello all. Got a question. I am wiring an office building for a family member's used car lot. The building was a two story split level residential home with a basement that is being converted to …
What year were you required to use 14/2 12/2 Romex WITH A GROUND.
Apr 23, 2024 · All 12/2 or 14/2 cloth Romex and range cable was cloth covered 3 wire. 10-2 cloth Romex to water heater. 60 amp panel was grounded to water line nearby. I first noticed grounded …
Romex in conduit attached to an enclosure (indoors), fastening ...
Dec 17, 2024 · When using conduit to protect Romex before it enters an enclosure - for example, coming up out of the crawlspace, up an un-finished wall to a disconnect - what fastening …
Garage romex protection | Information by Electrical Professionals for ...
Mar 29, 2010 · Where in the code is it required, (or not) the need to protect NM cable run in a garage, horizontally through bored holes in stud runs that are exposed (not covered with drywall? Items can …
Romex and SER ampacities. | Information by Electrical Professionals for ...
May 12, 2021 · As far as SER it seems that #4 is the best choice for a 60 amp feeder cable, (if we can use 75 degrees) since it is usually readily available, and #4 romex would be severe overkill. Talking …
Romex Connectors installed from the inside of the box
Jul 23, 2007 · Does anyone know of a romex connector that can be installed from the inside of an EXISTING junction box. I can't access the outside of the box without opening up the drywall, and the …
Spray Foam & Romex | Information by Electrical Professionals for ...
Jul 28, 2021 · So hoping I can get a little help/advice here. Had my attic ceiling spray foam insulation done. All along the perimeter it becomes pretty tights. I had a bunch romex run along the rafters …
Romex Wire | Information by Electrical Professionals for Electrical ...
Feb 9, 2023 · romex the temp rating for nm-b is 90c but we have to use the 60 degree column for the proper sizing i have ran into some jobs for example they ran #8 romex from breaker then finished off …